ALMIRA OBSERVATORY
 

     A suburban observatory in Worcestershire, UK based on a metal garden shed

           
  Home   Observations   Useful links

 

  Construction 10 - External Electrics

 

 

The observatory is served by an electrical feed from an outside socket on the side of the house.  This a double switched socket with integral RCD and rated to IP65.  The feed is a 22 metre (72 feet) length of heavy duty three core flex with a 2.5mm wire cross section.  This flex runs through polyethylene water pipe set a minimum of 30cm (1 foot) below the patio and lawn with electrical warning  tape above the pipe.  Water pipe was chosen because it is tough, flexible (to a point) and would have no underground joints; thus preventing water and creepy-crawlies getting into the pipe.

     

     
  A second length of water pipe was laid next to the one carrying the flex.  This carries two lengths of nylon cord and was installed so that network cabling could be installed later as required.
     
  ◄ Previous Page            1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16             Next Page ►

Last updated -  27th April 2013

Copyrightę 2006-2013 Michael Morris